Content: 100 assays per kit
Shipping Temperature: Ambient
Storage Temperature: Short term stability: 2-8oC,
Long term stability: See individual component labels
Stability: > 1 year under recommended storage conditions
Analyte: endo-Cellulase, β-Glucanase/Lichenase
Assay Format: Spectrophotometer
Detection Method: Absorbance
Wavelength (nm): 590
Signal Response: Increase
Limit of Detection: 100 U/kg of malt
Reproducibility (%): ~ 7%
Reaction Time (min): ~ 35 min
Application examples: Malt extracts, wort, beer and other materials.
Method recognition: RACI Standard Method
β-Glucanase (Malt and Microbial) Assay Kit is suitable for the measurement and analysis of malt and bacterial β-glucanase and endo-1,4-β-glucanase.
Looking for other assay kits? See our full range of enzyme assay kits.
Advantages
Very cost effective
All reagents stable for > 2 years during use
Only kit available
Very specific
Simple format
Standard included
内容:每个试剂盒100个分析
运输温度:环境温度
储存温度:短期稳定性:2-8oC,
长期稳定性:参见单个组件标签
稳定性:在推荐的储存条件下>1年
分析物:内切纤维素酶、β-葡聚糖酶/Lichenase
测定形式:分光光度计
检测方法:吸光度
波长(nm):590
信号响应:增加
检测限:100 U/kg麦芽
再现性(%):~7%
反应时间(分钟):~35分钟
应用实例:麦芽提取物、麦芽汁、啤酒等原料。
方法识别:RACI标准方法
β-葡聚糖酶(麦芽和微生物)检测试剂盒适用于麦芽和细菌β-葡聚糖蛋白酶以及内切-1,4-β-葡聚糖酶类的测量和分析。
正在寻找其他检测试剂盒?查看我们的全套酶分析试剂盒。
优点
极具成本效益
所有试剂在使用期间稳定超过2年
仅提供套件
非常具体
简单格式
包含标准
The MW’s were determined by Multiangle laser light scattering technique.
Barley beta-glucan lot 30108 would contain about 3-4% arabinoxylan (this was produced in 1993). Material supplied post 1995 contains < 0.5.% arabinoxylan. Carob galactomannan is quite pure (> 96%).
The content of 1,3 bonds in barley beta-glucan is about 32% (from literature). We would not expect this to change much (if at all) over different batches.
The substrates are enzymically treated to yield the required viscosity (20 ~ 30 cSt). Modification of the viscosity of beta-glucan is required for IOB viscometric malt beta-glucanase test (which works well).
The pH of the assay solution after the sample is added should be the same as that of the assay buffer that is supplied with the kit.
Low sample volumes (e.g. 0.1 mL) are not likely to affect the pH of the assay solution and therefore may not require pH adjustment.
Samples above 0.1 mL are more likely to affect the pH of the assay solution and therefore the pH of these samples should be adjusted as described in the data booklet, prior to addition to the assay.
If you suspect that the Megazyme test kit is not performing as expected such that expected results are not obtained please do the following:
For glucanase assay we recommend the medium viscosity beta-glucan. We now offer low, medium and high viscosity wheat arabinoxylans, and we think that the low viscosity material will be best (easiest) to use in the reducing-sugar assay.