Content: 50 assays per kit
Shipping Temperature: Ambient
Storage Temperature: Short term stability: 2-8oC,
Long term stability: See individual component labels
Stability: > 2 years under recommended storage conditions
Analyte: Fructan
Assay Format: Spectrophotometer
Detection Method: Absorbance
Wavelength (nm): 340
Signal Response: Increase
Linear Range: 4 to 80 µg of D-glucose, D-fructose or sucrose per assay
Limit of Detection: 1 g/100 g
Total Assay Time: ~ 30 min
Application examples: Flours, plant materials (e.g. onion), food products and other materials
Advantages
Very cost effective
All reagents stable for > 12 months after preparation
Fructan kits are available only from Megazyme
Simple format
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
The Fructan HK test kit is suitable for the specific measurement and analysis of all fructo-oligosaccharides (reducing and non-reducing) and of fructan polysaccharides but is not suitable for the analysis of samples containing high levels of D-glucose, D-fructose, sucrose or maltose.
内容:每个试剂盒50次检测
运输温度:环境温度
储存温度:短期稳定性:2-8oC,
长期稳定性:参见单个组件标签
稳定性:在推荐的储存条件下超过2年
分析物:果聚糖
测定形式:分光光度计
检测方法:吸光度
波长(nm):340
信号响应:增加
线性范围:每次测定4至80µg D-葡萄糖、D-果糖或蔗糖
检测限:1 g/100 g
总测定时间:约30分钟
应用示例:面粉、植物材料(如洋葱)、食品和其他材料
优点
极具成本效益
所有试剂在制备后可稳定12个月以上
果聚糖试剂盒只能从Megazyme获得
简单格式
Mega Calc™ 我们的网站上提供了软件工具,可以轻松处理原始数据
包含标准
果聚糖HK检测试剂盒适用于所有低聚果糖(还原性和非还原性)和果聚糖多糖的特定测量和分析,但不适用于分析含有高水平D-葡萄糖、D-果糖、蔗糖或麦芽糖的样品。
The pH of the assay solution after the sample is added should be the same as that of the assay buffer that is supplied with the kit.
Low sample volumes (e.g. 0.1 mL) are not likely to affect the pH of the assay solution and therefore may not require pH adjustment.
Samples above 0.1 mL are more likely to affect the pH of the assay solution and therefore the pH of these samples should be adjusted as described in the data booklet, prior to addition to the assay.
Sometimes the addition of the last assay component can cause a small negative absorbance change in the blank samples due to a dilution effect and in such cases it is recommended that the real absorbance values be used in the calculation of results.
If you suspect that the Megazyme test kit is not performing as expected such that expected results are not obtained please do the following:
Where the amount of analyte in a liquid sample is unknown, it is recommended that a range of sample dilutions are prepared with the aim of obtaining an absorbance change in the assay that is within the linear range.
Where solid samples are analysed, the weight of sample per volume of water used for sample extraction/preparation can be altered to suit, as can the dilution of the extracted sample prior to the addition of the assay, as per liquid samples.
If there are any concerns with any kit components, the first thing to do is to test the standard sample (control sample) that is supplied with the kit and ensure that the expected value (within the accepted variation) is obtained before testing any precious samples. This must be done using the procedure provided in the kit booklet without any modifications to the procedure. If there are still doubts about the results using the standard sample in the kit then send example results in the MegaCalc spread sheet to your product supplier (Megazyme or your local Megazyme distributor).
The volume/weight of sample and total volume of the extract can be modified to suit the sample. This will ultimately be dictated by the amount of analyte of interest in the sample and may require empirical determination. For low levels of analyte the sample:extract volume ratio can be increased (i.e. increase the sample and/or decrease the total extraction volume).
Alternatively, for samples with low concentrations of analyte, a larger sample volume can be added to the kit assay. When altering the sample volume adjust the distilled water volume added to the assay accordingly so that the total assay volume is not altered.
The kit assay may work for biological fluids assuming that inositol is present above the limit of detection for the kit after any sample preparation (if required). Centrifugation of the samples and use of the supernatant directly in the kit assay (with appropriate dilution in distilled water) may be sufficient. However, if required a more stringent sample preparation method may be required and examples are provided at the following link:http://www.megazyme.com/docs/analytical-applications-downloads/biological_samples_111109.pdf?sfvrsn=2
The test kit has not been tested using biological fluids as samples because it is not marketed or registered as a medical device. This will therefore require your own validation.
The majority of the Megazyme test kits are developed to work in cuvettes using the manual assay format, however the assay can be converted for use in a 96-well microplate format. To do this the assay volumes for the manual cuvette format are reduced by 10-fold. The calculation of results for the manual assay format uses a 1 cm path-length, however the path-length in the microplate is not 1 cm and therefore the MegaCalc spreadsheet or the calculation provided in the kit booklet for the manual format cannot be used for the micropalate format unless the microplate reader being used can.
There a 3 main methods for calculation of results using the microplate format:
For samples with low concentrations of analyte the sample volume used in the kit assay can be increased to increase sensitivity. When doing this the water volume is adjusted to retain the same final assay volume. This is critical for the manual assay format because the assay volume and sample volume are used in the calculation of results.
The test kit is extremely accurate – at Megazyme the quality control criteria for accuracy and repeatability is to be within 2% of the expected value using pure analytes.
However, the level of accuracy is obviously analyst and sample dependent.
No. The 0.1 change of absorbance is only a recommendation. The lowest acceptable change in absorbance can is dictated by the analyst and equipment (i.e. pipettes and spectrophotometer) and therefore can be can be determined by the user. With accurate pipetting, absorbance changes as low as 0.02 can be used accurately.
If a change in absorbance above 0.1 is required but cannot be achieved due to low concentrations of analyte in a sample, this can be overcome by using a larger sample volume in the assay to increase the absorbance change and thereby increase sensitivity of the assay. When doing this the increased volume of the sample should be subtracted from the distilled water volume that is added to the assay so that the total assay volume is unaltered. The increase sample volume should also be accounted for when calculating final results.
Yes. Samples with the lower concentrations of analyte will generate a lower absorbance change. For samples with low concentrations of analyte, a larger sample volume can be used in the assay to increase the absorbance change and thereby increase sensitivity of the assay. When doing this the increased volume of the sample should be subtracted from the distilled water volume that is added to the assay so that the total assay volume is unaltered. The increase sample volume should also be accounted for when calculating final results.
Megazyme果聚糖[HK法]试剂盒FructanHK操作视频(K-FRUCHK)
Megazyme 溶解淀粉 操作视频
Megazyme 试剂盒样品前处理准备操作视频
最有帮助的评价(0)
暂时还没有任何用户评论-